Inflaming Retarding LSZH Crolinking sheath Shielded Twisted pair CAT5e Ethernet Cable/T-CC009

Crosslinking low smoke halogen cable has very excellent flame retardant performance, but also has strong overload capacity, load capacity and the advantages of large insulation resistance, suitable for high buildings, hotels, shopping malls, stadiums, transportation hub, entertainment places need high flame retardant halogen, low smoke, non-toxic, no corrosive gas crowded area. Especially suitable for rail transit on-board PIS system, the relevant national standards have clearly required the on-board PIS system to give priority to the use of cross-linked sheath cables. Cross-link low smoke halogen free flame retardant sheath shield multi-stranded cable fully meet the relevant national standards.

Features:
Super 5 class 22 wire gauge 4, cross isolation and copper mesh weaving and aluminum foil double total shielding, copper net weaving density is more than 80%; super 5 class 22 wire gauge 2 double shielding cross-link, copper net weaving density is more than 85%. The special cross-linked low smoke halogen-free flame retardant sheath has large flow capacity, large insulation resistance, long service life, strong overload capacity, environmental protection, safety POE +). And other characteristics, no halogen, low smoke, non-toxic, no corrosion. Support for Ethernet power supply (Power over Ethernet) applications (POE)
Application
SF/UTP,CAT5E,AWG22, indoor
High buildings, hotels, shopping malls, stadiums, transportation hub, entertainment places need high flame retardant halogen, low smoke, non-toxic, no corrosive gas crowded area. Especially suitable for rail transit on-board PIS system, the relevant national standards have clearly required the on-board PIS system to give priority to the use of cross-linked sheath cables.

 

Specification:
Transmission performance CAT 5E
Frequency(MHz) 4 10 20 31.25 62.5 100 150
Attenuation IL(DB/100M) 3.9 5.8 8.1 10.1 15.4 20 21.5
Near end crosstalk attenuation(NEXT)(dB) 82.1 85 65 60 60 50 48
The um of proximal crosstalk attenuation power PS NEXT(dB) 80.3 82.4 62.9 58.3 57.9 49.3 46
Equal-level distal crosstalk attenuation(ACR-F)(dB) 81.6 80.9 75.6 65.6 63.7 59 55.8
Equal-level distal crosstalk attenuation power PS (ACR-F)(dB) 79.8 78.1 72.6 65.6 63.7 59 55.8
Echo loss PL (dB) 31.2 32.9 38.8 33.7 23.8 26.2 24.9

 

Electric property
Direct-current resistance 145Ω/KM
Earth capacity ≤5.6nF/100m(@1KHZ)
100 MHZ characteristic resistance 100Ω±15Ω
Transverse transformation and loss of TCL ≥55dB(30-100MHZ)
Delay deviation 45ns/100m
NVP 65%
Ethernet Power Supply (POE) IEEE 802.3at Enhanced Ethernet
Mechnical performance
Minimum bending radius (Static) 28mm
Minimum bending radius (dynamic) 56mm
Max installation Tensile 100N
Anti compressing value 1000N/10cm
Compassion resistance ≥10 times
Installastion temperature -0ºC~+40ºC
Working temperature -40ºC~+80ºC