Shanghai Gengyun Industrial Co., Ltd
Double-Shielded (S / FTP) Copper Cable Cat8 Ethernet Cable/T-CC001
S / FTP, indoor cable Class 8 lines are a new generation of dual-shielded (S / FTP) network cables, with four wire pairs, 2000 MHz bandwidth and a high transmission rate of 40 Gb / s over a distance of 30 meters. It is particularly suitable for connecting servers, switches, panels, and other devices in a data center. Cat. 8. 1 / 8. Class 2 network cable is downward compatible with Cat. 7 / 7A and Cat. 6A | ||||
The network cable, which can support 25G Base-T at a distance of more than 30 meters (tentative) and 10G Base-T at a distance of 100 meters, can be applied to high speed and bandwidth dense places outside the data center, and can also support Ethernet power supply (Power over Ethernet) applications (POE / POE +). |
Application standards: |
GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc |
Features: |
S / FTP, Cat. 8. 1 / 8. 2, Class I / II, AWG 23, indoor cable |
Class 8 lines are a new generation of dual-shielded (S / FTP) network cables, with four wire pairs, 2000 MHz bandwidth and a high transmission rate of 40 Gb / s over a distance of 30 meters. It is particularly suitable for connecting servers, switches, panels, and other devices in a data center. Cat. 8. 1 / 8. [] Class 2 network cable is downward compatible with Cat. 7 / 7A and Cat. 6A |
The network cable, which can support 25G Base-T at a distance of more than 30 meters (tentative) and 10G Base-T at a distance of 100 meters, can be applied to high speed and bandwidth dense places outside the data center, and can also support Ethernet power supply (Power over Ethernet) applications (POE / POE +). |
Application standards: |
GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc |
Specification: | ||||||
Transmission performance | ||||||
Frequency(MHz) | 4 | 300 | 600 | 1000 | 1600 | 2000 |
Attenuation IL(DB/100M) | 3.7 | 10.7 | 15.1 | 17.9 | 22.0 | 28.5 |
Near end crosstalk attenuation(NEXT)(dB) | 115.0 | 125.2 | 110.7 | 122.4 | 99.3 | 92.9 |
The um of proximal crosstalk attenuation power PS NEXT(dB) | 80.0 | 80.0 | 75.8 | 72.5 | 69.4 | 68.0 |
Equal-level distal crosstalk attenuation(NEXT)(dB) | 75.0 | 50.8 | 44.7 | 40.3 | 36.2 | 34.6 |
Equal-level distal crosstalk attenuation power PS NEXT(dB)(NEXT)(dB) | 80.0 | 52.7 | 46.6 | 42.2 | 38.1 | 36.2 |
Echo loss PL (dB) | 23.0 | 18.9 | 16.8 | 15.2 | 13.8 | 13.1 |