Shanghai Gengyun Industrial Co., Ltd
Outdoor Direct Burial Anti-termite Anti-rodent Fiber Optic Cable With LSZH Jacket
The Anti-termite fiber optic cable, 250um, are positioned in a loose tube made of a high module plastic. The tubes ate filled wth a water-resistant filling compound. Direct Burial Anti-termite fiber optic cable has good mechanical, temperature performance, is suitable for long-distance outdoor communication.
The Anti-termite anti-rodent fiber optic cable, 250um, are positioned in a loose tube made of a high module plastic. The tubes ate filled wth a water-resistant filling compound. A steel wire located in the center of core as a metallic strength member into a compact and circular cable core. An Aluminium Polyethylene Laminate (APL) applied around the direct burial fiber optic cable core. Which filled with the filling compound to protect it front water ingress. Then the cable core covered with a PE outer sheath. After the single steel armored, the cable finally completed with an outer sheath.
Feature
- Outdoor Direct Burial fiber optic cable Good mechanical and temperature performance;
- Outdoor optical fiber Single-steel ensures good performance of tensile strength;
- High strength loose tube that is hydrolysis resistant;
- Special tube filling compound ensure a critical protection of fiber;
- Crush resistance and flexibility;
- The Anti-termite anti-rodent fiber optic cable take following measures to ensure the cable watertight:
- Steel wire used as the central strength member;
- Loose tube filling compound;
- 100% cable core filling;
- APL moisture barrier;
- PSP enhancing moisture-proof;
- Water-blocking;
- LSZH Jacket;
Application of Anti-rodent Fiber Optic Cable
Direct Burial Anti-termite fiber optic cable is suitable for long-distance communication and outdoor communication.
Specification
- Way of laying: Direct burial, pipeline;
- Direct Burial Anti-termite Fiber Optic Cable Operating temperature: -40 ~ + 70 ° C;
- Bending Radius: Static 12.5*Cable-diameter: Dynamic 25*Cable-diameter;
Technical Parameter
Cable Type | Fiber Count | Tubes | Fillers | Cable Weight Kg/km |
Tensile Strength Long/Short term N |
Crush Resistance Long/Short term N |
Bending Radius Static / Dynamic mm |
GYTA53+33-2 ~ 6 | 2 ~ 6 | 1 | 5 | 819 | 4000/10000 | 3000/5000 | 12.5D/25D |
GYTA53+33-8 ~ 12 | 8 ~ 12 | 2 | 4 | 819 | |||
GYTA53+33-14 ~ 18 | 14 ~ 18 | 3 | 3 | 819 | |||
GYTA53+33-20 ~ 24 | 20 ~ 24 | 4 | 2 | 819 | |||
GYTA53+33-26 ~ 30 | 26 ~ 30 | 5 | 1 | 819 | |||
GYTA53+33-32 ~ 3 6 | 32 ~ 3 6 | 6 | 0 | 819 | |||
GYTA53+33-2 ~ 6 | 2 ~ 6 | 1 | 5 | 1002 | 10000/20000 | ||
GYTA53+33-8 ~ 12 | 8 ~ 12 | 2 | 4 | 1002 | |||
GYTA53+33-14 ~ 18 | 14 ~ 18 | 3 | 3 | 1002 | |||
GYTA53+33-20 ~ 24 | 20 ~ 24 | 4 | 2 | 1002 | |||
GYTA53+33-26 ~ 30 | 26 ~ 30 | 5 | 1 | 1002 | |||
GYTA53+33-32 ~ 3 6 | 32 ~ 3 6 | 6 | 0 | 1002 |