T-CC006 Cat3 Ethernet Cable Unshielded Large-Log Twisted-Pair Copper Cable

Indoor cable lines are a new generation of dual-shielded (S / FTP) network cables, with four wire pairs, 2000 MHz bandwidth and a high transmission rate of 40 Gb / s over a distance of 30 meters. It is particularly suitable for connecting servers, switches, panels, and other devices in a data center. Cat. 8. 1 / 8. Class 2 network cable is downward compatible with Cat. 7 / 7A and Cat. 6A
The network cable, which can support 25G Base-T at a distance of more than 30 meters (tentative) and 10G Base-T at a distance of 100 meters, can be applied to high speed and bandwidth dense places outside the data center, and can also support Ethernet power supply (Power over Ethernet) applications (POE / POE +).

Cat3 network cable usually use 24AWG to 27AWG copper core wires, and use TP (Twisted Pair) to wind the wires in pairs. This structure helps reduce electromagnetic interference. In addition to used for Ethernet transmission, Cat3 ethernet cable also commonly used in two-line telephone systems and some low-speed network applications. Such as alarm system installation or similar applications. Due to its relatively low price, it still used in some occasions where the transmission rate not required. Although the anti-interference performance of Cat3 network cables is not as good as that of more advanced network cables. Such as Cat5e, Cat6, etc.  It can still provide sufficient anti-interference performance in the application scenarios for which it designed to ensure stable data transmission.

Application standards

GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc

 

Features

CAT 3 ethernet cable types of unshielded large log cables increase the stranded density, the insulation sheath adopts high quality HDPE insulation material. The product transmission rate of 16MHZ, for voice transmission and 10 BASE-T network applications.

Operating temperature: -20ºC ~ + 75ºC

Packaging mode: 305 m

box application standard GB / T 18233 (ISO / IEC 11801); GB 50311; TIA / EIA568-C. 2, etc

1. Anti-interference: Although the anti-interference performance of Cat3 network cable is not as good as that of more advanced network cables. Such as Cat5e, Cat6, etc. But in the application scenarios for which it designed, it can still provide sufficient anti-interference performance to ensure stable data transmission.
2. Cost-effectiveness: Compared with more advanced network cables, Cat3 network cables have lower costs. Therefore, it still a viable option in some occasions with strict cost requirements.

Application standards:
It is used for the transmission of main voice and data in the building communication integrated cabling system, mainly used for the vertical trunk line of the building voice system. Large logarithmic twisted-pair is an indispensable link in the building. Combined with 110 wiring frame equipment, it can realize voice or data transmission and wiring.